We studied and planned a new system at energetic transfer able to go beyond the traditional limits.
With the Energetic transfer by endogenous type, a special method, called OMNIPOLAR (uni-polar) system has been optimized; it takes the body as “reference” and concentrates all the energy on the emitters hand-pieces.
On the BODY and on the Face.
Energy Transfer for Perfect Shape
Close documentation
We studied and planned a new system at energetic transfer able to go beyond the traditional limits.
With the Energetic transfer by endogenous type, a special method, called OMNIPOLAR (uni-polar) system has been optimized; it takes the body as “reference” and concentrates all the energy on the emitters hand-pieces.
On the BODY: works by activating the lipolytic enzymes which are sensitive to heat, reducing consequently the adipose tissue. Activates fibroblasts to produce new collagen fibers. Increases vascularization facilitating the lymphatic drainage with detoxification and oxygenation, allowing the absorption of the active ingredients used in products. On the handpiece we have also added LED at 880 nm + 640 nm as carriers for a better result.
On the Face: causes an immediate contraction of the collagen fibers, accelerate the metabolism of fibroblasts resulting in generation of new collagen and elastin. The emission of infrared wave lenght to 880 nm, is able to interact with the cells’ ability to capture enough energy to stimulate a biological response of tissues. Technique that has proved effective in some treatments to combat skin aging.
The vibration of high-frequency ULTRASOUNDS through tissues determines a change in pressure in the tissue itself (mechanical effect) and a part of energy is transformed into heat (thermal effect with vasodilatation) exercising, consequently, a micro massage.
The factors which make HF Ultrasound particularly effective are:
• It is possible to act on all cellulite stages and fat accumulation.
• It can act on the affected area only.
• No collateral effects since the “fusion” of the subcutaneous fat and the crushing of the fibrotic tissue not occur via drug but thanks to its mechanical and thermal action.
The high-frequency ultrasounds in the Dual ET are equipped with an electronic filtering of ultrasonic modulation for the elimination of noise pollution derived by the ”sub harmonic” oscillation of piezoelectrics, in compliance with applicable regulations to protect hearing of the operator in the workplace and that of the treated subject.
Main technical specifications Dual ET 7.11
Type
Electrostatic Capacitive accumulation energy transfer generator.
High frequency U.S generator.
Power supply via power supply unit
external specified
power supply voltage: 12 V DC
max. power absorbed: 132 VA
Transducers
small hand piece diam 50 mm. (E.T. + I.R.)
medium hand piece diam. 100 mm. (E.T. + RGBY)
large hand piece diam. 110 mm. (high freq. U.S.)
E.T. applicative resonance power
Variable and programmed automatically depending
on the hand pieces used: Min. 15 W - Max. 30 W
E.T. Frequency
1 MHz ca.
Chromatic emission power
Max 4 W (R+B+G+Y)
Applications
Mono-polar/CAPACITIVE - (single pole)
U.S. emitter power
Maximum power surface density on the transducer
2,8 - 3,0 W/cm/2
U.S. Frequency
transducer oscillation about 3 MHz
Container
Plexiglass / metal
Dimensions - without trolley /with trolley
cm. 39 x 39 x 14 / 55 x 55 x 101 ( l x p x h )
Dimensions including package
cm. 65 x 65 x 94
Weight
Kg. 6,5 / Kg. 13,0 - with pakage Kg 16,0
Display
Touch Screen Color 7'' in diag.
Device
Class II Type BF
Compliancy with Laws and Regulations
Community Directives:
2004 / 108 / CE
2006 / 95 / CE
CEI 62 . 39
FINCARD srl
reserves the right to modify the above without any prior notice, but will maintain the
characteristics of safety and electrical-magnetic compatibility, required by Community Regulations.
All FINCARD - MAXBEAUTY devices have been designed and built according to electrical safety requirements and electromagnetic compatibility requirements indicated by European Union Regulations and applicable IEC, CENELEC and CEI norms.
Each model is subject to tests performed by an independent laboratory, documented by official test reports, proving compliancy of the norms.
Standard production of each article is controlled and inspected individually, according to extremely strict control and measuring protocols.
The FINCARD – MAXBEAUTY devices all bear the brand that guarantees a high level of quality and allows for the product to be sold in any country.
Compliancy statements and other documentation proving its compliancy are available to all clients.